{"product_id":"easemed-urobitur-urology-electrosurgical-generator-cautery-machine-unit-bipolar-saline-turp-set","title":"EASEMED UROBITUR Urology Electrosurgical Generator Cautery Machine Unit | Bipolar Saline TURP Set","description":"\u003ch1 class=\"PDq2pG_selectionAnchorContainer\"\u003eProduct Description\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch2\u003eEASEMED UROBITUR Urology Electrosurgical Generator – Bipolar Technology for TURP\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eEASEMED UROBITUR Electrosurgical Generator\u003c\/strong\u003e is an advanced urology electrosurgical unit designed specifically for \u003cstrong\u003eBipolar TURP and Saline TURP procedures\u003c\/strong\u003e. It combines bipolar, monopolar, coagulation, cutting, and sealing functions in a versatile electrosurgical platform for professional urological applications.\u003c\/p\u003e\n\u003cp\u003eThe UROBITUR features a \u003cstrong\u003e7-segment LED display\u003c\/strong\u003e for clear power indication and user-friendly controls for convenient operation. With a \u003cstrong\u003emaximum output power of up to 400W\u003c\/strong\u003e and multiple operating modes, the system provides flexible energy delivery for different surgical requirements.\u003c\/p\u003e\n\u003cp\u003eThe unit supports \u003cstrong\u003eBi-Cut, Bi-Coag, Bipolar, Seal and Saline TURP modes\u003c\/strong\u003e, making it suitable for a wide range of urological electrosurgical procedures. It also offers \u003cstrong\u003e99 user-programmable programs\u003c\/strong\u003e, allowing customized settings for professional surgical use.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Bipolar Technology\u003c\/strong\u003e – Designed for bipolar electrosurgical applications including TURP.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBipolar Saline TURP Support\u003c\/strong\u003e – Suitable for procedures requiring bipolar technology with saline irrigation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUp to 400W Maximum Output\u003c\/strong\u003e – Provides high-power capability for demanding electrosurgical applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMultiple Operating Modes\u003c\/strong\u003e – Includes Bi-Cut, Bi-Coag, Bipolar, Seal and Saline TURP functions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e7-Segment LED Display\u003c\/strong\u003e – Clear digital indication of selected power settings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e99 User-Programmable Programs\u003c\/strong\u003e – Allows customized operating settings for different procedures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecise Power Adjustment\u003c\/strong\u003e – Separate controls for Bi-Cut and Bi-Coag output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfessional Urology Application\u003c\/strong\u003e – Designed for use in urological surgical environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ch3\u003eBi-Cut (Monopolar)\u003c\/h3\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eMode\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eMaximum Power\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eLoad\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eCrest Factor\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePure Cut\u003c\/td\u003e\n\u003ctd\u003e140 W\u003c\/td\u003e\n\u003ctd\u003e500 Ω\u003c\/td\u003e\n\u003ctd\u003e1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlend 1\u003c\/td\u003e\n\u003ctd\u003e120 W\u003c\/td\u003e\n\u003ctd\u003e500 Ω\u003c\/td\u003e\n\u003ctd\u003e1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlend 2\u003c\/td\u003e\n\u003ctd\u003e100 W\u003c\/td\u003e\n\u003ctd\u003e500 Ω\u003c\/td\u003e\n\u003ctd\u003e1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEndocut\u003c\/td\u003e\n\u003ctd\u003e99%\u003c\/td\u003e\n\u003ctd\u003e500 Ω\u003c\/td\u003e\n\u003ctd\u003e1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eBi-Coag (Monopolar)\u003c\/h3\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eMode\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eMaximum Power\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eLoad\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eCrest Factor\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpray\u003c\/td\u003e\n\u003ctd\u003e120 W\u003c\/td\u003e\n\u003ctd\u003e500 Ω\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForce\u003c\/td\u003e\n\u003ctd\u003e120 W\u003c\/td\u003e\n\u003ctd\u003e500 Ω\u003c\/td\u003e\n\u003ctd\u003e6.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFulgurate\u003c\/td\u003e\n\u003ctd\u003e150 W\u003c\/td\u003e\n\u003ctd\u003e500 Ω\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDesiccate\u003c\/td\u003e\n\u003ctd\u003e150 W\u003c\/td\u003e\n\u003ctd\u003e500 Ω\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eBipolar Modes\u003c\/h3\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eMode\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eMaximum Power\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eLoad\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eCrest Factor\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMicro\u003c\/td\u003e\n\u003ctd\u003e80 W\u003c\/td\u003e\n\u003ctd\u003e100 Ω\u003c\/td\u003e\n\u003ctd\u003e1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMacro\u003c\/td\u003e\n\u003ctd\u003e80 W\u003c\/td\u003e\n\u003ctd\u003e100 Ω\u003c\/td\u003e\n\u003ctd\u003e1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto Bipolar\u003c\/td\u003e\n\u003ctd\u003e100 W\u003c\/td\u003e\n\u003ctd\u003e100 Ω\u003c\/td\u003e\n\u003ctd\u003e1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eBipolar \/ Seal \/ Saline TURP\u003c\/h3\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eMode\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eMaximum Power\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eLoad\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eCrest Factor\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBi-Coag \/ Micro\u003c\/td\u003e\n\u003ctd\u003e80 W\u003c\/td\u003e\n\u003ctd\u003e100 Ω\u003c\/td\u003e\n\u003ctd\u003e1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBi-Cut \/ Macro\u003c\/td\u003e\n\u003ctd\u003e80 W\u003c\/td\u003e\n\u003ctd\u003e100 Ω\u003c\/td\u003e\n\u003ctd\u003e1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto\u003c\/td\u003e\n\u003ctd\u003e100 W\u003c\/td\u003e\n\u003ctd\u003e100 Ω\u003c\/td\u003e\n\u003ctd\u003e1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeal\u003c\/td\u003e\n\u003ctd\u003e150 W\u003c\/td\u003e\n\u003ctd\u003e100 Ω\u003c\/td\u003e\n\u003ctd\u003e1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eGeneral Specifications\u003c\/h3\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEASEMED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eURO BITUR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBipolar Technology for TURP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Output Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7-Segment LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrograms\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e99 User Programmable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSalient Specifications\u003c\/h3\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency – Monopolar\/TURP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e480 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency – Seal Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7-Segment LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Supply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230\/110 VAC (±15%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAs specified on supplied product specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eEASEMED UROBITUR Electrosurgical Generator\u003c\/strong\u003e is designed primarily for professional \u003cstrong\u003eurology and TURP applications\u003c\/strong\u003e, including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBipolar TURP\u003c\/li\u003e\n\u003cli\u003eSaline TURP\u003c\/li\u003e\n\u003cli\u003eUrological electrosurgery\u003c\/li\u003e\n\u003cli\u003eBipolar cutting procedures\u003c\/li\u003e\n\u003cli\u003eBipolar coagulation procedures\u003c\/li\u003e\n\u003cli\u003eElectrosurgical tissue cutting and coagulation\u003c\/li\u003e\n\u003cli\u003eUrological procedures requiring bipolar technology\u003c\/li\u003e\n\u003cli\u003eSeal-mode applications where applicable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"PDq2pG_selectionAnchorContainer\"\u003eStandard Accessories\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eChuck Handle with Electrodes\u003c\/li\u003e\n\u003cli\u003eBipolar Forceps with Cable\u003c\/li\u003e\n\u003cli\u003eMonopolar \/ Bipolar \u0026amp; Seal Double Footswitch\u003c\/li\u003e\n\u003cli\u003eDisposable Hand Switch Pencil\u003c\/li\u003e\n\u003cli\u003ePatient Plate with Cord\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eWarranty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e1 Year Warranty Included\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eEASEMED UROBITUR\u003c\/strong\u003e comes with a \u003cstrong\u003e1-year warranty\u003c\/strong\u003e against manufacturing defects under normal operating conditions. Warranty coverage is subject to the applicable terms and conditions. Damage caused by misuse, unauthorized servicing, physical damage, or improper operation may not be covered.\u003c\/p\u003e","brand":"INSTRUMED HEALTHCARE","offers":[{"title":"Default Title","offer_id":46989040812231,"sku":null,"price":79999.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/0319\/7895\/files\/EASEMEDUROBITURUrologyElectrosurgicalGeneratorCauteryMachineUnitforBipolarSalineTURPSet.png?v=1786607629","url":"https:\/\/instrumedshealthcare.com\/products\/easemed-urobitur-urology-electrosurgical-generator-cautery-machine-unit-bipolar-saline-turp-set","provider":"Instrumed Healthcare","version":"1.0","type":"link"}